sane−p5 - Online Linux Manual PageSection : 5
Updated : 15 Feb 2010
Source :
Note : SANE Scanner Access Now Easy
.IX sane−p5
NAMEsane−p5 − SANE backend for the Primax PagePartner
DESCRIPTIONThe sane−p5 library implements a SANE (Scanner Access Now Easy) backend that provides access to the Primax PagePartner parallel port sheet fed scanner. This backend handles 100, 150, 200, 300 and 600 dpi scan resolutions, in color and gray modes. The 600 dpi is actually 300x600 with lines enlarged to match the vertical resolution. EPP/ECP MODES ONLY The current version of the backend uses only EPP or ECP mode to communicate with the scanner. It is recommended that you set your parallel port to EPP in BIOS with the current version of this backend. ECPEPP will only work if you use a 2.4 or 2.6 kernel with ppdev character device support.
DEVICE NAMESThis backend expects device names of the form: port value Where value is : auto autodetect all parallel ports and probe them for scanner /dev/parport0 uses linux ppdev device, depending on the number of available parallel port, you have to use /dev/parport1, /dev/parport2, ... You can rename any device using the
option name my_name option. This option apply to the last port option.
CONFIGURATIONPlease make sure to edit dll.conf before you use the backend, since this backend isn't enabled by default.
FILES/etc/sane.d/p5.conf The backend configuration file (see also description of SANE_CONFIG_DIR below). /usr/lib64/sane/libsane−p5.a The static library implementing this backend. /usr/lib64/sane/libsane−p5.so The shared library implementing this backend (present on systems that support dynamic loading).
ENVIRONMENTSANE_CONFIG_DIR This environment variable specifies the list of directories that may contain the configuration file. On *NIX systems, the directories are separated by a colon (`:'), under OS/2, they are separated by a semi-colon (`;'). If this variable is not set, the configuration file is searched in two default directories: first, the current working directory (".") and then in /etc/sane.d. If the value of the environment variable ends with the directory separator character, then the default directories are searched after the explicitly specified directories. For example, setting SANE_CONFIG_DIR to "/tmp/config:" would result in directories tmp/config, ., and /etc/sane.d" being searched (in this order). SANE_DEBUG_P5 If the library was compiled with debug support enabled, this environment variable controls the debug level for this backend. E.g., a value of 255 requests all debug output to be printed. Smaller levels reduce verbosity. level debug output
−−−−−−− −−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
0 critical errors
1 errors
2 warnings & minor errors
4 information messages
8 start/stop of functions
16 tracing messages
32 I/O functions
64 I/O functions with traces
128 scanned/calibration data
SEE ALSOsane(7), sane−net(5), saned(8), scanimage(1)
AUTHORStéphane Voltz <stef.dev@free.fr>
CREDITSSupport for the Prima PagePartner has been made possible thank to an hardware donation by Sébastien Lange.
BUG REPORTSIf something doesn't work mail sane-devel@alioth-lists.debian.net or submit an issue via https://gitlab.com/sane-project/backends/issues/new with a label of backend/p5. Please give as much information as you can. SANE version run "scanimage −V" to determine this the backend version and your scanner hardware run SANE_DEBUG_P5=255 scanimage −L 2>log" as root. If you don't get any output from the p5 backend, make sure a line "p5" is included into your /etc/sane.d/dll.conf. If your scanner isn't detected, make sure you've defined the right port address, or the correct device in your p5.conf. the name of your scanner/vendor also a worthy information. Please also include the optical resolution and lamp type of your scanner, both can be found in the manual of your scanner. any further comments if you have comments about the documentation (what could be done better), or you think I should know something, please include it. 0
Johanes Gumabo
Data Size : 13,303 byte
man-sane-p5.5Build : 2024-12-05, 20:55 :
Visitor Screen : x
Visitor Counter ( page / site ) : 2 / 201,150
Visitor ID : :
Visitor IP : 3.135.209.20 :
Visitor Provider : AMAZON-02 :
Provider Position ( lat x lon ) : 39.962500 x -83.006100 : x
Provider Accuracy Radius ( km ) : 1000 :
Provider City : Columbus :
Provider Province : Ohio , : ,
Provider Country : United States :
Provider Continent : North America :
Visitor Recorder : Version :
Visitor Recorder : Library :
Online Linux Manual Page : Version : Online Linux Manual Page - Fedora.40 - march=x86-64 - mtune=generic - 24.12.05
Online Linux Manual Page : Library : lib_c - 24.10.03 - march=x86-64 - mtune=generic - Fedora.40
Online Linux Manual Page : Library : lib_m - 24.10.03 - march=x86-64 - mtune=generic - Fedora.40
Data Base : Version : Online Linux Manual Page Database - 24.04.13 - march=x86-64 - mtune=generic - fedora-38
Data Base : Library : lib_c - 23.02.07 - march=x86-64 - mtune=generic - fedora.36
Very long time ago, I have the best tutor, Wenzel Svojanovsky . If someone knows the email address of Wenzel Svojanovsky , please send an email to johanes_gumabo@yahoo.co.id .
If error, please print screen and send to johanes_gumabo@yahoo.co.id
Under development. Support me via PayPal.
ERROR : Need New Coding : (parse_manual_page_|249|sane-p5.5|2|IX|.IX sane\-p5
)